Common errors of FUJI Inverter and How to fix them
In the previous part, we have learned about communication errors, accessory errors, operation errors, errors due to inverter output. Continue the series of common errors on Fuji Electric in this part , Hao Phuong would like to send to the customer the error correction solution related to the connection, host and card option
-
ER8 – RS485 Error
|
Possible causes |
Checking & Fixing |
1 |
Connection standard between different inverter and host |
Compare the y function settings (Y01, Y10) with the host. |
2 |
Although Y08 has been installed, the connection is not installed correctly as the workflow |
Check the host. Change the Host software, or ignore the error (Y08) |
3 |
Host controls incorrectly or software / hardware errors |
Check the host |
4 |
The converter (RS485) is incorrect between connection and installation or hardware failure |
Check RS485 Change RS485 converter, reconnect or change hardware. |
5 |
Connection loss due to cable breakage or bad contact |
Check cables, contact points. |
6 |
Large noise signal caused to the drive |
Check the installation of the inverter in accordance with the working environment conditions. |
-
ERH – Hardware Error
|
Possible causes |
Checking & Fixing |
1 |
Card option is broken |
replace card option |
-
ECF – EN terminal Circuit Error
|
Possible |
Checking & Fixing |
1 |
The circuit is damaged |
Change control circuit |
-
PG – Disconnection Error
|
Possible |
Checking & Fixing |
1 |
Some signals between the encoder and option card are broken |
Check the connection between the encoder and the option card. |
2 |
Large noise signal caused to the drive |
Check installation of inverters in accordance with working environment conditions. |
Hao Phuong specializes in distributing genuine electrical and industrial equipment from reputable manufacturers in the region and the world. Contact Hotline 1800 6547 to get more information about the product as well as Hao Phuong’s policy.